VEVOR Fully Automatic Recovery Machine Refrigerant Recovery Machine for R134A & R1234YF (AC Recovery Machine Kit with Electronic Scale, Compressor, Recovery Tank)
Category: Refrigerant Recovery
Check Current PriceVEVOR Fully Automatic Recovery Machine Refrigerant Recovery Machine for R134A & R1234YF fits small shops. It recovers R134A and R1234YF at an average 100-250 g/min recovery rate. This Refrigerant Recovery tool includes a built-in compressor, electronic scale, and a 15kg recovery tank.
VEVOR Fully Automatic Recovery Machine benefits for small auto shops
VEVOR Fully Automatic Recovery Machine delivers automated Refrigerant Recovery with an integrated compressor, scale, and vacuum filtration for faster workflows. The kit supports both R134A and R1234YF so shops can service older and newer vehicles without swapping machines. Recovery efficiency rates approach 95 percent while average gas recovery runs 100-250 g/min, which reduces time spent on each A/C job. The built-in 7-inch touch screen and 0.5 g scale simplify weighing, documentation, and reduce human error during refrigerant transfers.
How much garage floor space and electrical power required?
VEVOR Refrigerant Recovery Machine requires 120V 60Hz power and a stable bench or cart for placement. The compressor draws 600W during normal operation, so a dedicated 15 A circuit provides reliable power and prevents nuisance tripping. Shops should allocate a secure, level surface near the service bay for the recovery tank and hoses; the manufacturer does not publish dimensions so safe bench mounting is prudent. Secure placement reduces vibration, prevents accidental hose strain, and speeds technician access during Refrigerant Recovery jobs.
Why fully automatic refrigerant recovery suits small auto shops
Fully Automatic Recovery Machine Refrigerant Recovery Kit for AC Systems reduces procedural steps by automating recovery, weighing, and filtering cycles for consistency. Automation removes manual valve juggling and scale checks, which lowers technician training time and reduces human error during refrigerant transfers. The machine s automatic cutoffs and integrated filtration also protect compressors and improve refrigerant purity before reuse or return to cylinders. Small shops gain throughput advantages because one technician can run recovery while performing other tasks, increasing billable labor per hour.
What EPA regulations, certifications, and documentation apply?
Fully Automatic Recovery Machine follows EPA rules that prohibit intentional refrigerant venting under the Clean Air Act. Automotive technicians must hold EPA Section 609 certification to service motor vehicle A/C systems and to purchase certain refrigerants. Shops must use approved recovery equipment and avoid venting; if shops transfer refrigerant to cylinders, they should follow cylinder labeling and safe storage best practices. Documentation of recovered refrigerant weight using the machine s electronic scale helps demonstrate compliance and supports warranty or service records.
VEVOR Fully Automatic Recovery Machine maintenance and total operating costs
VEVOR refrigerant recovery kit with built-in electronic scale, compressor and recovery tank for R134A/R1234YF minimizes recurring labor but does incur consumable and service costs. The unit includes two 300 ml oil bottles (new and used) which require replacement after oil changes, and shops should budget for filter elements and periodic scale fuse replacements. The machine s electronic scale accuracy of 0.5 g and 15 kg cylinder capacity reduce overfill risk, but shops should still account for cylinder procurement, refrigerant purchasing, and the occasional compressor service. Third-party protection plans, such as Asurion-style coverage, can lower out-of-pocket repair costs for parts and labor when offered.
Component specifications and service-related numbers for cost estimates
- Power input: 120V 60Hz
- Compressor power: 600W
- Average recovery rate: 100-250 g/min
- Charge speed: 800-1000 g/min
- Gas cylinder capacity: 15 kg
- Electronic scale accuracy: 0.5 g
- New and used oil bottle capacity: 300 ml each
- Max pressure rating: 18 bar
VEVOR Fully Automatic Recovery Machine operators should expect consumable costs from oil, filters, and occasional fittings replacements that together typically form the bulk of annual maintenance spend. Warranty and protection plans may shift repair risk, but shops should track hours of use to compare to service milestones. The integrated design reduces the need for separate compressor and scale purchases, which lowers initial kit costs versus buying components piecemeal.
How often should compressors, filters, and oil be serviced?
VEVOR refrigerant recovery kit with built-in electronic scale, compressor and recovery tank for R134A/R1234YF recommends routine inspection and periodic service based on usage intensity. Common industry practice calls for oil checks with every 20-50 service hours and oil replacement every 50-200 hours, depending on contaminant loads and manufacturer guidance. Replace filtration elements when vacuum pulling time increases or after major system contamination events; track filter life by hours or refrigerant mass processed. For heavy-shop use, plan compressor preventive maintenance every 1,000 operational hours or every two to three years, and always follow the manufacturer s service instructions when available.
Common follow-up questions technicians search after reading
How do I pick correct hoses and fittings for different car manufacturers? Use quick-connect fittings supplied for imperial threads, and source metric adapters when needed from the seller. What safety gear and ventilation should shops use during recovery operations? Wear goggles and gloves, and ensure shop ventilation when evacuating systems to prevent inhalation of oil or refrigerant vapors. How much should I budget for consumables in year one? Expect initial consumable spend on oil, filters, and small fittings plus occasional replacement parts; exact totals vary with job volume.